HPLC Purity (RP-C18, UV-DAD)
Reverse-phase gradient elution adapted from USP <621>. Reports area-percent purity with full chromatogram and integration table.
Peptide Testing Laboratory
SteriGenix is a US-based contract analytical laboratory specializing in research-grade peptides and small-molecule compounds. Every batch we analyze is logged under a unique identifier, run on validated instrumentation, and returned with a Certificate of Analysis anyone can verify on the public portal.
What We Test
Reverse-phase gradient elution adapted from USP <621>. Reports area-percent purity with full chromatogram and integration table.
Electrospray (ESI) in positive and negative mode per USP <736>. Mass accuracy ±0.01 Da against the theoretical monoisotopic mass.
Kinetic chromogenic LAL per USP <85>. Detection to 0.005 EU/mL using Charles River Endosafe.
Gravimetric and volumetric fill checks against label claim, including assay-corrected active content.
Coulometric titration per USP <921> Method 1c. Critical for lyophilized peptide stability.
Headspace GC-MS per USP <467> for ICH Q3C Class 1, 2, and 3 solvents.
Why It Matters
The research-compound supply chain has historically run on supplier-issued certificates with no independent verification path. Forged COAs, copy-pasted chromatograms, and conflicts of interest are common — and buyers have no way to tell a real document from a generated one.
A SteriGenix peptide test is the alternative. We do not manufacture, distribute, or sell the compounds we test. Every assay is run, reviewed, and signed by a third party with no commercial interest in the result.
Each report links to retained chromatograms, mass spectra, and integration files held for a minimum of three years. Anyone can paste the batch identifier into the public Verify portal and confirm the certificate's authenticity.
The result: research suppliers, formulators, and downstream buyers can stop arguing about whose word to take and start pointing at the same data set.
Process
Email cs@sterigenixanalytical.com or use the Contact form to receive a submission number and shipping label.
5–10 mg of dry powder is sufficient for HPLC + LC-MS. 25 mg recommended for full panels with LAL and KF.
Standard turnaround 5 business days from receipt; rush 3-day service available at +50%.
Signed PDF delivered with raw chromatograms; batch ID is publicly verifiable on /verify.
We respond within one business day with a submission number, current pricing, and preferred shipping protocol for your compound class.
Contact the LabSteriGenix Lab
Independent peptide analytics